FT 10-RH-PS-E4
Order reference:
FT 10-RH-PS-E4Product number:
600-11000Scope of delivery:
Operating manual, Sensor, Jaw clampsShort description:
10...70mm, red light, BGS, teach-in, PNP, M5 4-pin plug. There is a new variant for this product: 600-11048 FT 10-RH-PNSL-E4. It offers additional functions via IO-Link. Product information can be found at www.sensopart.de
Description
- Adjustable background suppression up to a scanning distance of 70 mm
- Static or dynamic teach-in via teach-in button and control line
- Button locking via control line
- N.O./N.C. changeover via teach-in button and control line
- MBD F 10 dovetail design bracket included in the scope of delivery
| Opticial data | ||
|---|---|---|
| Gray and white offset 20%/90% | 3.0 | |
| Explanation of gray and white offset 20%/90% | At the end of the operating range, gray (20%) | |
| Black and white offset 5%/90% | 4.0 | |
| Explanation of black and white offset 5%/90% | At the end of the operating range, black (5%) | |
| Hysteresis [mm] | 2.0 | |
| Explanation of hysteresis | At the end of the operating range | |
| Light source | LED | |
| Light color | Red | |
| Wavelength [nm] | 650 | |
| Light spot size [mm] | See diagram | |
| Switching frequency ≤ [Hz] | ≤ 1,000 | |
| Explanation of switching frequency | f (ti/tp 1:1) | |
| Working range [mm] | 4 ... 70 | |
| Explanation working range | Reference material white, 90% remission | |
| Setting range [mm] | 10 ... 70 | |
| Explanation of the setting range | Reference material white, 90% remission | |
| Functions | ||
|---|---|---|
| Display, LED yellow | Switching output indicator | |
| Display, LED green | Operating voltage indicator | |
| Setting options | N.O./N.C. via teach-in button and control input Button lock via control input | |
| Scanning distance adjustment | via teach-in button and control input | |
| Teach-in modes | Mode 1: while the process is running Mode 2: when the process is stopped | |
| Default settings | max. Working range and N.O | |
| Electronic data | ||
|---|---|---|
| Operating voltage UB [V DC] | 10 ... 30 | |
| Explanation of operating voltage UB | max. 10% residual ripple, within UB, ~ 50 Hz/100 Hz | |
| No-load current [mA] | ≤ 20 | |
| Output current [mA] | ≤ 50 | |
| Readiness delay [ms] | ≤ 300 | |
| Reverse polarity protection | Yes | |
| Short circuit protection | Yes | |
| Response time Q [µs] | ≤ 500 | |
| Control input | +UB = Teach-in -UB = Button locked Open = normal operation | |
| Protection class | 2 | |
| Output function | N.O./N.C. | |
| Switching output Q | PNP | |
| Mechanical data | ||
|---|---|---|
| Height [mm] | 8.0 | |
| Length [mm] | 21.1 | |
| Width [mm] | 14.6 | |
| Weight [g] | ~ 3 | |
| Front panel material | PMMA | |
| Housing material | PUR | |
| Ambient temperature: operation [°C] | -20 ... 60 | |
| Explanation of operation at ambient air temperature | UL: -20…+30 °C | |
| Ambient temperature: storage [°C] | -20 ... 80 | |
| Protection class | IP 67 | |
| Explanation of protection class | with IP 67 plug connected | |
| Connection name | Plug, M5x0.5, 4-pin | |
| Classification Reference Features | ||
|---|---|---|
| Light scanner, energetic | EC001821 | ETIM 6.0 |
| Light scanner, energetic | EC001821 | ETIM 7.0 |
| Lichttaster energetisch | EC001821 | ETIM 8.0 |
| Light scanner, energetic | 27270903 | ECLASS 10.1 |
| Light scanner, energetic | 27270903 | ECLASS 11.0 |
| Light scanner, energetic | 27270903 | ECLASS 11.1 |
| Light scanner | 27270903 | ECLASS 12.0 |
| Light scanner | 27270903 | ECLASS 13.0 |