FT 25-RLAP-1500-PNSUL-M4M
Order reference:
FT 25-RLAP-1500-PNSUL-M4MProduct number:
604-41015Scope of delivery:
Operating manual, Sensor, Laser warning signsShort description:
Distance sensor with time-of-flight measurement, 0.1...1.5 m, laser, analogue 1...10 V, Auto-detect, N.O./N.C., metal plug M8 4-pin, IP 67 & IP 69, IO-Link
Description
- Reliable measured value output – Stable and precise measurement results thanks to proven time-of-flight technology
- Flexible configuration – analogue and switching output individually adjustable, simple adjustment via teach function using button
- Long range with compact design – object detection/distance measurement up to 1.5 m in a miniature housing (34 x 20 x 12 mm)
- Excellent detection properties – reliable detection on almost all surfaces such as metal or colored plastic
- Precisely adjustable background suppression
- Easy integration and adjustment – clearly visible light spot for quick alignment and easy installation even in confined spaces
- Reliable operation without additional protective measures – laser class 1 for safe operation
| Opticial data | ||
|---|---|---|
| Setting range [mm] | 100 ... 1,500 | |
| Explanation of the setting range | Reference material white, 90% remission | |
| Resolution [mm] | 0.340 | |
| Explanation of resolution | QA, 12 bit | |
| Linearity [mm] | 15.00 | |
| Explanation of linearity | Specification ±; reference material, 5...90% remission; see graph for typical values | |
| Repeatability [mm] | ≤ 7.00 | |
| Explanation of repeatability | 2...7 mm; white reference material, 90% remission; at 50 Hz/10 ms; homogeneous, stationary object; see graph for typical values | |
| Light source | Laser | |
| Laser class | 1 (IEC 60825-1) | |
| Light color | Red | |
| Wavelength [nm] | 658 | |
| Light spot size [mm] | See diagram | |
| Switching frequency ≤ [Hz] | ≤ 300 | |
| Explanation of switching frequency | At 800 mm; white reference material, 90% remission | |
| Switching hysteresis [mm] | 4.0 | |
| Explanation of switching hysteresis | 4...7 mm; white reference material, 90% remission; at 5 Hz/100 ms | |
| IO-Link resolution [mm] | 0.10 | |
| Measured value refresh time | Response time QA + averaging rate | |
| Functions | ||
|---|---|---|
| Averaging times | 5 Hz/100 ms, 10 Hz/50 ms, 50 Hz/10 ms, 100 Hz/5 ms, 200 Hz/2 ms, 300 Hz/1 ms, | |
| Connection, BK | Switching output Q/IO-Link | |
| Connection, WH | Analogue output QA | |
| Display, LED yellow | Switching output indicator Q | |
| Display, LED green | Operating voltage indicator | |
| Setting options | Measurement range QA Switching output Q (switching window) Parallel shifting of the analogue characteristic curve QA to a new reference level via AutoCenter N.O. / N.C. and Auto-detect / PNP / NPN Switchover averaging Q / QA via teach-in button and IO-Link Wide range of setting options for service and process data via IO-Link | |
| Default settings | Analogue output QA 1...10 V, 100...1500 mm Switching output Q: Switching window 100...1500 mm, N.O. | |
| Measuring range adjustment | via teach-in button and IO-Link | |
| Electronic data | ||
|---|---|---|
| Operating voltage UB [V DC] | 18 ... 30 | |
| Explanation of operating voltage UB | max. 10% residual ripple, within UB, ~ 50 Hz / 100 Hz | |
| No-load current [mA] | ≤ 30 | |
| Output current [mA] | ≤ 100 | |
| Readiness delay [ms] | ≤ 300 | |
| Reverse polarity protection | Yes | |
| Short circuit protection | Yes | |
| Analog output QA | 1 ... 10 V / max. 3 mA | |
| Measured value output | Analog (voltage), IO Link | |
| Protection class | 2 | |
| Output function | N.O./N.C. | |
| Number of outputs | 2 | |
| Warm-up time [Min.] | 15 | |
| Temperature profile [mm/K] | 0.80 | |
| Explanation of thermal response | Reference material white, 90% remission | |
| Averaging times | 5 Hz/100 ms, 10 Hz/50 ms, 50 Hz/10 ms, 100 Hz/5 ms, 200 Hz/2 ms, 300 Hz/1 ms, | |
| Measured value refresh time | Response time QA + averaging rate | |
| Switching output Q | Auto-Detect, PNP, NPN | |
| Measured value output | Analog (voltage), IO Link | |
| IO-Link | ||
|---|---|---|
| Data storage | Yes | |
| Communication mode | COM 2 | |
| Length of the process data [Bit] | 32 | |
| Min. cycle time [ms] | 4.0 | |
| SIO mode | is supported | |
| IO-Link specification | 1.1 | |
| Mechanical data | ||
|---|---|---|
| Height [mm] | 34.0 | |
| Length [mm] | 20.0 | |
| Width [mm] | 12.0 | |
| Weight [g] | ~ 10 | |
| Front panel material | PMMA | |
| Housing material | ABS | |
| Ambient temperature: operation [°C] | -30 ... 50 | |
| Ambient temperature: storage [°C] | -20 ... 80 | |
| Protection class | IP 67, IP 69 | |
| Explanation of protection class | with IP 67 / IP 69 plug connected | |
| Vibration and shock resistance | EN IEC 60947-5-2 | |
| Connection name | Metal plug M8x1, 4-pin, IO-Link | |
| - Number of pins | 4 | |
| - Thread | M8x1 | |
| Classification Reference Features | ||
|---|---|---|
| Optical distance sensor | EC001825 | ETIM 6.0 |
| Optical distance sensor | EC001825 | ETIM 7.0 |
| Optischer Abstandssensor | EC001825 | ETIM 8.0 |
| Ultrasonic one-way barrier | 27270801 | ECLASS 10.1 |
| Optical distance sensor | 27270801 | ECLASS 11.0 |
| Optical distance sensor | 27270801 | ECLASS 11.1 |
| Optical distance sensor | 27270916 | ECLASS 12.0 |
| Optical distance sensor | 27270916 | ECLASS 13.0 |