orregistration
Search
Order code:
Order number:
Short description:
This product is no longer available, please contact our support.
35.000
8 μA
350.00
± 0.5%, reference material reflector RF250; of the set measurement range
≤ 1.50
at 1 σ, set measurement range < 20 m, for further values see diagram
Laser
1 (IEC 60825-1)
Red
655
≤ 50
ti/tp 1:1
60.0
LED 1 / LED 2 = switching output indicator
Betriebsspannungsanzeige
Adjustable analogue measurement range QA
Analogue characteristic curve invertible
Adjustable switching output Q (switching window)
N.O. / N.C. / antivalent Q1/Q1 and Auto-detect / NPN / PNP via teach-in button and control input
Button lock via control input
Analogue range QA (4...20 mA) Measurement range: 2...6 mSwitching output Q1 (A1...A2), N.O., Auto-detect Measuring range: 2...6 m
Switching output Q2 (A1...A2), N.O., Auto-detect Measurement range: 2...6 m
via teach-in button or control input
≤ 60
≤ 100
≤ 5,000
Yes
≤ 10,000
4 ... 20 mA
Control input IN 1 and IN 2:
+ UB = teach-in- UB = button locked
Open = normal operation
Control input IN 3:
+ UB = laser off- UB = laser on
open = laser on
Analog (current)
2
500
≤ 500 Ohm (4...20 mA)
N.O./N.C./antivalent Q1
Auto-detect (PNP/NPN)
Auto-detect: automatic selection of PNP or NPN by sensor, PNP or NPN can be configured permanently
3
20
1.000
< 1 mm / K
50.1
50.0
23.0
~ 42
PMMA
ABS
IP 67, IP 69K
With IP 67/ IP 69K plug connected
EN 60947-5-2
Plug, M12x1, 8-pole
8
M12x1
Cuboidal
Wish list