Skip to main content
Standardsensoren

IMT 8-S-NB2-PSL-M3M

Order reference:

IMT 8-S-NB2-PSL-M3M

Product number:

996-01007

Short description:

Inductive sensor, M8 housing, non-flush, Sn= 4 mm, PNP/NO, M8 3-pin plug, IO-Link

Description

  • Various parameter configuration options
  • IO-Link 1.1
Functions
Display, LED yellow

Switching output indicator

Setting options

N.O. / N.C. Wide range of setting options via IO-Link

Default settings

NO

IO-Link

Yes

Temperature drift [mm/K]

0.160

Explanation of temperature drift

≤ 10% Sr

Techhnical data
Reduction factor, Al

0.45

Reduction factor, Cu

0.40

Reduction factor, steel FE 360

1.00

Correction factor, V2A

0.75

Correction factor, CuZn

0.50

Repeatability [mm]

≤ 0.20

Rated switching distance, Sn [mm]

4.0

Switching frequency ≤ [Hz]

≤ 3,500

Ensured switching distance [mm]

≤ 3.240

Rated switching distance, Sn [mm]

4.0

Standard measurement plate

12 mm x 12 mm x 1 mm (FE 360)

Electronic data
Operating voltage UB [V DC]

10 ... 30

No-load current [mA]

≤ 10

Output current [mA]

≤ 200

Readiness delay [ms]

≤ 80

Reverse polarity protection

Yes

Short circuit protection

Yes

Output function

N.O./N.C.

Explanation of output function

Can be set / configured via IO-Link

Residual current, Ir [µA]

≤ 100.0

Residual ripple [%]

≤ 20

Switching output Q

PNP

Voltage drop U [V]

2.0

Explanation of voltage drop U

≤ 2 V DC at 200 mA

Inductive protection

Yes

Mechanical data
Housing material

Stainless steel, V2A

Connection name

Stainless steel plug, V2A, M8x1, 3-pin

Installation

not flush

Length [mm]

45.0

Weight [g]

~ 12

Housing material

Stainless steel, V2A

Material, active surface

PBTP Crastin

Ambient temperature: operation [°C]

-25 ... 70

Ambient temperature: storage [°C]

-25 ... 70

Protection class

IP 67

Explanation of protection class

with IP 67 plug connected

Vibration and shock resistance

EN IEC 60947-5-2

Connection name

Stainless steel plug, V2A, M8x1, 3-pin, IO-Link

- Number of pins

3

- Thread

M8x1

Installation

not flush

Housing type

Cylindrical

Max. tightening torque [Nm]

0.30

Standard measurement plate

12 mm x 12 mm x 1 mm (FE 360)

Classification Reference Features
Inductive distance sensor EC001818ETIM 6.0
Inductive distance sensor EC001818ETIM 7.0
Induktiver Abstandssensor EC001818ETIM 8.0
Keine Klasse zu diesem Artikel in dieser Version enthalten 00000000ECLASS 10.1
Keine Klasse zu diesem Artikel in dieser Version enthalten 00000000ECLASS 11.0
Keine Klasse zu diesem Artikel in dieser Version enthalten 00000000ECLASS 11.1
Inductive proximity switch 27274001ECLASS 12.0
Inductive proximity switch 27274001ECLASS 13.0
MC 08

MC 08.mounting bracket FM 08 Material: AlMgSi0.5 Accessories, bracket, mounting bracket for M8 series

Our website is available in different languages. We have detected "English" as your browser language or couldn't detect your language.