Skip to main content
Standardsensoren

IMT 18-S-NB2-PSL-L4M

Order reference:

IMT 18-S-NB2-PSL-L4M

Product number:

996-01011

Short description:

Inductive sensor, M18 housing, non-flush, Sn= 12 mm, PNP/NO, M12 4-pin plug, IO-Link

Description

  • Various parameter configuration options
  • IO-Link 1.1
Functions
Display, LED yellow

Switching output indicator

Setting options

N.O. / N.C. Wide range of setting options via IO-Link

Default settings

NO

IO-Link

Yes

Temperature drift [mm/K]

0.240

Explanation of temperature drift

≤ 10% Sr

Techhnical data
Reduction factor, Al

0.45

Reduction factor, Cu

0.40

Reduction factor, steel FE 360

1.00

Correction factor, V2A

0.75

Correction factor, CuZn

0.55

Repeatability [mm]

≤ 0.60

Rated switching distance, Sn [mm]

12.0

Switching frequency ≤ [Hz]

≤ 500

Ensured switching distance [mm]

≤ 9.720

Rated switching distance, Sn [mm]

12.0

Standard measurement plate

36 mm x 36 mm x 1 mm (FE 360)

Electronic data
Operating voltage UB [V DC]

10 ... 30

No-load current [mA]

≤ 10

Output current [mA]

≤ 200

Readiness delay [ms]

≤ 60

Reverse polarity protection

Yes

Short circuit protection

Yes

Output function

N.O./N.C.

Explanation of output function

Can be set / configured via IO-Link

Residual current, Ir [µA]

≤ 100.0

Residual ripple [%]

≤ 20

Switching output Q

PNP

Voltage drop U [V]

2.0

Explanation of voltage drop U

≤ 2.0 V DC at 100 mA

Inductive protection

Yes

Mechanical data
Housing material

Brass, nickel-plated

Connection name

Metal plug M12x1, 4-pole

Installation

not flush

Length [mm]

63.5

Weight [g]

~ 51

Housing material

Brass, nickel-plated

Material, active surface

PBTP Crastin

Ambient temperature: operation [°C]

-25 ... 70

Ambient temperature: storage [°C]

-25 ... 70

Protection class

IP 67

Explanation of protection class

with IP 67 plug connected

Vibration and shock resistance

EN IEC 60947-5-2

Connection name

Metal plug, M12x1, 4-pin, IO-Link

- Number of pins

4

- Thread

M12x1

Installation

not flush

Housing type

Cylindrical

Max. tightening torque [Nm]

25.00

Standard measurement plate

36 mm x 36 mm x 1 mm (FE 360)

Classification Reference Features
Inductive distance sensor EC001818ETIM 6.0
Inductive distance sensor EC001818ETIM 7.0
Induktiver Abstandssensor EC001818ETIM 8.0
Keine Klasse zu diesem Artikel in dieser Version enthalten 00000000ECLASS 10.1
Keine Klasse zu diesem Artikel in dieser Version enthalten 00000000ECLASS 11.0
Keine Klasse zu diesem Artikel in dieser Version enthalten 00000000ECLASS 11.1
Inductive proximity switch 27274001ECLASS 12.0
Inductive proximity switch 27274001ECLASS 13.0
MC 18

Retaining clip for round M18 housings

Our website is available in different languages. We have detected "English" as your browser language or couldn't detect your language.